Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeOther
Built-in depth69mm
Rated current10A
Over voltage category3
Pollution degree3
Release characteristicC
Explosion-proofNo
Rated insulation voltage Ui440V
Frequency50 - 60Hz
Rated voltage440V
Power loss4.3W
Width in number of modular spacings2.0
Current limiting class3
Number of protected poles2
Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Connectable conductor cross section solid-core0.75 - 35mm²
Flush-mounted installationNo
Ambient temperature during operating-40 - 75°C
Additional equipment possibleYes
Connectable conductor cross section multi-wired0.75 - 25mm²
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS272565R0104 | S202MTR-C10 DC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Built-in depth

69mm

Rated current

10A

Over voltage category

3

Pollution degree

3

Release characteristic

C

Explosion-proof

Rated insulation voltage Ui

440V

Frequency

50 .. 60Hz

Rated voltage

440V

Power loss

4.3W

Width in number of modular spacings

2.0

Current limiting class

3

Number of protected poles

2

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Connectable conductor cross section solid-core

0.75 .. 35mm²

Flush-mounted installation

Ambient temperature during operating

-40 .. 75°C

Additional equipment possible

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Concurrently switching neutral conductor

Degree of protection (IP)

IP20