Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated voltage440V
Voltage typeOther
Number of protected poles2
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Built-in depth69mm
Number of poles (total)2
Power loss4.3W
Rated current16A
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Release characteristicC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Current limiting class3
Width in number of modular spacings2.0
Connectable conductor cross section multi-wired0.75 - 25mm²
Additional equipment possibleYes
Pollution degree3
Over voltage category3
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Ambient temperature during operating-40 - 75°C
Degree of protection (IP)IP20
Connectable conductor cross section solid-core0.75 - 35mm²
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS272565R0164 | S202MTR-C16 DC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Professional worker

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated voltage

440V

Voltage type

Other

Number of protected poles

2

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Built-in depth

69mm

Number of poles (total)

2

Power loss

4.3W

Rated current

16A

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Release characteristic

C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Current limiting class

3

Width in number of modular spacings

2.0

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Additional equipment possible

Pollution degree

3

Over voltage category

3

Flush-mounted installation

Concurrently switching neutral conductor

Ambient temperature during operating

-40 .. 75°C

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0.75 .. 35mm²

Explosion-proof

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.