Aleta.hr
Main Product Image

2CDS272565R0377 | S202MTR-K6 DC

Code: 2003077

ManufacturerRAZNO
Catalog number2CDS272565R0377
Type
EAN code4016779121651

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Rated current

6A

Number of poles (total)

2

Release characteristic

K

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Number of protected poles

2

Voltage type

Other

Rated voltage

440V

Frequency

50 - 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Power loss

3.2W

Rated impulse withstand voltage Uimp

4kV

Current limiting class

3

Additional equipment possible

Yes

Width in number of modular spacings

2.0

Pollution degree

3

Over voltage category

3

Concurrently switching neutral conductor

No

Connectable conductor cross section solid-core

0.75 - 35mm²

Ambient temperature during operating

-40 - 75°C

Connectable conductor cross section multi-wired

0.75 - 25mm²

Flush-mounted installation

No

Explosion-proof

No

Degree of protection (IP)

IP20

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CDS272565R0377 | S202MTR-K6 DC

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Rated current

6A

Number of poles (total)

2

Release characteristic

K

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Number of protected poles

2

Voltage type

Other

Rated voltage

440V

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Power loss

3.2W

Rated impulse withstand voltage Uimp

4kV

Current limiting class

3

Additional equipment possible

Width in number of modular spacings

2.0

Pollution degree

3

Over voltage category

3

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

0.75 .. 35mm²

Ambient temperature during operating

-40 .. 75°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Flush-mounted installation

Explosion-proof

Degree of protection (IP)

IP20

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.