Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Rated current6A
Number of poles (total)2
Release characteristicK
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Number of protected poles2
Voltage typeOther
Rated voltage440V
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Power loss3.2W
Rated impulse withstand voltage Uimp4kV
Current limiting class3
Additional equipment possibleYes
Width in number of modular spacings2.0
Pollution degree3
Over voltage category3
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core0.75 - 35mm²
Ambient temperature during operating-40 - 75°C
Connectable conductor cross section multi-wired0.75 - 25mm²
Flush-mounted installationNo
Explosion-proofNo
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS272565R0377 | S202MTR-K6 DC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Professional worker

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Rated current

6A

Number of poles (total)

2

Release characteristic

K

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Number of protected poles

2

Voltage type

Other

Rated voltage

440V

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Power loss

3.2W

Rated impulse withstand voltage Uimp

4kV

Current limiting class

3

Additional equipment possible

Width in number of modular spacings

2.0

Pollution degree

3

Over voltage category

3

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

0.75 .. 35mm²

Ambient temperature during operating

-40 .. 75°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Flush-mounted installation

Explosion-proof

Degree of protection (IP)

IP20