Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Over voltage category3
Degree of protection (IP)IP20
Rated voltage440V
Current limiting class3
Concurrently switching neutral conductorNo
Frequency50 - 60Hz
Width in number of modular spacings2.0
Rated insulation voltage Ui440V
Voltage typeOther
Power loss6W
Connectable conductor cross section solid-core0.75 - 35mm²
Number of protected poles2
Explosion-proofNo
Built-in depth69mm
Connectable conductor cross section multi-wired0.75 - 25mm²
Ambient temperature during operating-40 - 75°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Additional equipment possibleYes
Flush-mounted installationNo
Pollution degree3
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated current20A
Release characteristicK
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS272565R0487 | S202MTR-K20 DC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Over voltage category

3

Degree of protection (IP)

IP20

Rated voltage

440V

Current limiting class

3

Concurrently switching neutral conductor

Frequency

50 .. 60Hz

Width in number of modular spacings

2.0

Rated insulation voltage Ui

440V

Voltage type

Other

Power loss

6W

Connectable conductor cross section solid-core

0.75 .. 35mm²

Number of protected poles

2

Explosion-proof

Built-in depth

69mm

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-40 .. 75°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Additional equipment possible

Flush-mounted installation

Pollution degree

3

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated current

20A

Release characteristic

K

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA