Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current16A
Rated voltage440V
Release characteristicC
Explosion-proofNo
Rated insulation voltage Ui440V
Voltage typeOther
Pollution degree3
Built-in depth69mm
Width in number of modular spacings3.0
Frequency50 - 60Hz
Over voltage category3
Current limiting class3
Power loss6.03W
Flush-mounted installationNo
Connectable conductor cross section solid-core0.75 - 35mm²
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Degree of protection (IP)IP20
Number of protected poles3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Additional equipment possibleYes
Connectable conductor cross section multi-wired0.75 - 25mm²
Ambient temperature during operating-25 - 55°C
Number of poles (total)3
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273065R0164 | S203MT-C16UC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

16A

Rated voltage

440V

Release characteristic

C

Explosion-proof

Rated insulation voltage Ui

440V

Voltage type

Other

Pollution degree

3

Built-in depth

69mm

Width in number of modular spacings

3.0

Frequency

50 .. 60Hz

Over voltage category

3

Current limiting class

3

Power loss

6.03W

Flush-mounted installation

Connectable conductor cross section solid-core

0.75 .. 35mm²

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Degree of protection (IP)

IP20

Number of protected poles

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Additional equipment possible

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-25 .. 55°C

Number of poles (total)

3

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA