  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Over voltage category3
Degree of protection (IP)IP20
Power loss9.54W
Concurrently switching neutral conductorNo
Voltage typeOther
Current limiting class3
Rated current32A
Number of protected poles3
Connectable conductor cross section solid-core0.75 - 35mm²
Frequency50 - 60Hz
Rated insulation voltage Ui440V
Rated voltage440V
Release characteristicC
Pollution degree3
Width in number of modular spacings3.0
Explosion-proofNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Ambient temperature during operating-25 - 55°C
Number of poles (total)3
Flush-mounted installationNo
Additional equipment possibleYes
Built-in depth69mm
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273065R0324 | S203MT-C32UC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Over voltage category

3

Degree of protection (IP)

IP20

Power loss

9.54W

Concurrently switching neutral conductor

Voltage type

Other

Current limiting class

3

Rated current

32A

Number of protected poles

3

Connectable conductor cross section solid-core

0.75 .. 35mm²

Frequency

50 .. 60Hz

Rated insulation voltage Ui

440V

Rated voltage

440V

Release characteristic

C

Pollution degree

3

Width in number of modular spacings

3.0

Explosion-proof

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-25 .. 55°C

Number of poles (total)

3

Flush-mounted installation

Additional equipment possible

Built-in depth

69mm

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA