Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency50 - 60Hz
Rated insulation voltage Ui440V
Over voltage category3
Voltage typeOther
Built-in depth69mm
Rated current4A
Rated voltage440V
Release characteristicZ
Current limiting class3
Degree of protection (IP)IP20
Explosion-proofNo
Power loss6.72W
Concurrently switching neutral conductorNo
Pollution degree3
Width in number of modular spacings3.0
Connectable conductor cross section solid-core0.75 - 35mm²
Number of protected poles3
Connectable conductor cross section multi-wired0.75 - 25mm²
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Flush-mounted installationNo
Number of poles (total)3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273065R0338 | S203MT-Z4UC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency

50 .. 60Hz

Rated insulation voltage Ui

440V

Over voltage category

3

Voltage type

Other

Built-in depth

69mm

Rated current

4A

Rated voltage

440V

Release characteristic

Z

Current limiting class

3

Degree of protection (IP)

IP20

Explosion-proof

Power loss

6.72W

Concurrently switching neutral conductor

Pollution degree

3

Width in number of modular spacings

3.0

Connectable conductor cross section solid-core

0.75 .. 35mm²

Number of protected poles

3

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Flush-mounted installation

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.