Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Current limiting class3
Degree of protection (IP)IP20
Release characteristicB
Concurrently switching neutral conductorNo
Rated current50A
Pollution degree3
Width in number of modular spacings3.0
Voltage typeOther
Power loss13.44W
Built-in depth69mm
Rated voltage440V
Over voltage category3
Rated insulation voltage Ui440V
Frequency50 - 60Hz
Explosion-proofNo
Number of protected poles3
Number of poles (total)3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Connectable conductor cross section solid-core0.75 - 35mm²
Flush-mounted installationNo
Additional equipment possibleYes
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Connectable conductor cross section multi-wired0.75 - 25mm²
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273065R0505 | S203MT-B50UC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Current limiting class

3

Degree of protection (IP)

IP20

Release characteristic

B

Concurrently switching neutral conductor

Rated current

50A

Pollution degree

3

Width in number of modular spacings

3.0

Voltage type

Other

Power loss

13.44W

Built-in depth

69mm

Rated voltage

440V

Over voltage category

3

Rated insulation voltage Ui

440V

Frequency

50 .. 60Hz

Explosion-proof

Number of protected poles

3

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Connectable conductor cross section solid-core

0.75 .. 35mm²

Flush-mounted installation

Additional equipment possible

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.