Over voltage category3
Rated current63A
Built-in depth69mm
Power loss16.35W
Current limiting class3
Release characteristicB
Pollution degree3
Explosion-proofNo
Rated insulation voltage Ui440V
Voltage typeOther
Rated voltage440V
Frequency50 - 60Hz
Width in number of modular spacings3.0
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0.75 - 25mm²
Additional equipment possibleYes
Concurrently switching neutral conductorNo
Number of protected poles3
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Flush-mounted installationNo
Ambient temperature during operating-25 - 55°C
Number of poles (total)3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Connectable conductor cross section solid-core0.75 - 35mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273065R0635 | S203MT-B63UC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Over voltage category

3

Rated current

63A

Built-in depth

69mm

Power loss

16.35W

Current limiting class

3

Release characteristic

B

Pollution degree

3

Explosion-proof

Rated insulation voltage Ui

440V

Voltage type

Other

Rated voltage

440V

Frequency

50 .. 60Hz

Width in number of modular spacings

3.0

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Additional equipment possible

Concurrently switching neutral conductor

Number of protected poles

3

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Flush-mounted installation

Ambient temperature during operating

-25 .. 55°C

Number of poles (total)

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Connectable conductor cross section solid-core

0.75 .. 35mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.