Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC
Rated voltage400V
Built-in depth69mm
Rated current1A
Frequency50 - 60Hz
Width in number of modular spacings3
Number of protected poles3
Concurrently switching neutral conductorNo
Current limiting class3
Over voltage category3
Rated insulation voltage Ui440V
Degree of protection (IP)IP20
Pollution degree3
Release characteristicZ
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V11.2kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Number of poles (total)3
Connectable conductor cross section multi-wired0 - 25mm²
Suitable for flush-mounted installationNo
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section solid-core0 - 35mm²
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273337R0218 | SU203M-Z1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Rated voltage

400V

Built-in depth

69mm

Rated current

1A

Frequency

50 .. 60Hz

Width in number of modular spacings

3

Number of protected poles

3

Concurrently switching neutral conductor

Current limiting class

3

Over voltage category

3

Rated insulation voltage Ui

440V

Degree of protection (IP)

IP20

Pollution degree

3

Release characteristic

Z

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

11.2kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Number of poles (total)

3

Connectable conductor cross section multi-wired

0 .. 25mm²

Suitable for flush-mounted installation

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section solid-core

0 .. 35mm²

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.