Technical specifications

Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Number of poles (total)3
Release characteristicZ
Number of protected poles3
Rated insulation voltage Ui440V
Rated current1A
Rated voltage400V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Current limiting class3
Frequency50 - 60Hz
Voltage typeAC
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V11.2kA
Width in number of modular spacings3
Over voltage category3
Pollution degree3
Additional equipment possibleYes
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0 - 25mm²
Connectable conductor cross section solid-core0 - 35mm²
Ambient temperature during operating-25 - 55°C
Built-in depth69mm
Concurrently switching neutral conductorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273337R0218 | SU203M-Z1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Number of poles (total)

3

Release characteristic

Z

Number of protected poles

3

Rated insulation voltage Ui

440V

Rated current

1A

Rated voltage

400V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Current limiting class

3

Frequency

50 .. 60Hz

Voltage type

AC

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

11.2kA

Width in number of modular spacings

3

Over voltage category

3

Pollution degree

3

Additional equipment possible

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0 .. 25mm²

Connectable conductor cross section solid-core

0 .. 35mm²

Ambient temperature during operating

-25 .. 55°C

Built-in depth

69mm

Concurrently switching neutral conductor

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.