Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency50 - 60Hz
Built-in depth69mm
Release characteristicC
Rated voltage400V
Pollution degree3
Voltage typeAC
Concurrently switching neutral conductorNo
Width in number of modular spacings3
Rated current30A
Over voltage category3
Degree of protection (IP)IP20
Rated insulation voltage Ui440V
Number of protected poles3
Current limiting class3
Suitable for flush-mounted installationNo
Additional equipment possibleYes
Connectable conductor cross section multi-wired0 - 25mm²
Number of poles (total)3
Connectable conductor cross section solid-core0 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V11.2kA
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273337R0304 | SU203M-C30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency

50 .. 60Hz

Built-in depth

69mm

Release characteristic

C

Rated voltage

400V

Pollution degree

3

Voltage type

AC

Concurrently switching neutral conductor

Width in number of modular spacings

3

Rated current

30A

Over voltage category

3

Degree of protection (IP)

IP20

Rated insulation voltage Ui

440V

Number of protected poles

3

Current limiting class

3

Suitable for flush-mounted installation

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 25mm²

Number of poles (total)

3

Connectable conductor cross section solid-core

0 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

11.2kA

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.