Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC
Frequency50 - 60Hz
Rated current40A
Rated voltage400V
Built-in depth69mm
Release characteristicZ
Rated insulation voltage Ui440V
Current limiting class3
Over voltage category3
Width in number of modular spacings3
Pollution degree3
Suitable for flush-mounted installationNo
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Number of protected poles3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V11.2kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Connectable conductor cross section multi-wired0 - 25mm²
Additional equipment possibleYes
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Number of poles (total)3
Connectable conductor cross section solid-core0 - 35mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273337R0558 | SU203M-Z40

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Frequency

50 .. 60Hz

Rated current

40A

Rated voltage

400V

Built-in depth

69mm

Release characteristic

Z

Rated insulation voltage Ui

440V

Current limiting class

3

Over voltage category

3

Width in number of modular spacings

3

Pollution degree

3

Suitable for flush-mounted installation

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Number of protected poles

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

11.2kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Connectable conductor cross section multi-wired

0 .. 25mm²

Additional equipment possible

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Number of poles (total)

3

Connectable conductor cross section solid-core

0 .. 35mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.