Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Release characteristicC
Rated current60A
Frequency50 - 60Hz
Rated voltage400V
Number of protected poles3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V11.2kA
Number of poles (total)3
Voltage typeAC
Rated insulation voltage Ui440V
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Suitable for flush-mounted installationNo
Concurrently switching neutral conductorNo
Pollution degree3
Over voltage category3
Width in number of modular spacings3
Built-in depth69mm
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section solid-core0 - 35mm²
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0 - 25mm²
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273337R0604 | SU203M-C60

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Professional worker

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Release characteristic

C

Rated current

60A

Frequency

50 .. 60Hz

Rated voltage

400V

Number of protected poles

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

11.2kA

Number of poles (total)

3

Voltage type

AC

Rated insulation voltage Ui

440V

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Suitable for flush-mounted installation

Concurrently switching neutral conductor

Pollution degree

3

Over voltage category

3

Width in number of modular spacings

3

Built-in depth

69mm

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section solid-core

0 .. 35mm²

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0 .. 25mm²

Additional equipment possible

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.