Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current8A
Voltage typeOther
Built-in depth69mm
Release characteristicK
Current limiting class3
Rated insulation voltage Ui440V
Number of protected poles3
Concurrently switching neutral conductorNo
Width in number of modular spacings3.0
Pollution degree3
Over voltage category3
Rated voltage400V
Frequency50 - 60Hz
Explosion-proofNo
Degree of protection (IP)IP20
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
Ambient temperature during operating-25 - 55°C
Power loss4.5W
Flush-mounted installationNo
Number of poles (total)3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273347R0407 | SU203MR-K8

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

8A

Voltage type

Other

Built-in depth

69mm

Release characteristic

K

Current limiting class

3

Rated insulation voltage Ui

440V

Number of protected poles

3

Concurrently switching neutral conductor

Width in number of modular spacings

3.0

Pollution degree

3

Over voltage category

3

Rated voltage

400V

Frequency

50 .. 60Hz

Explosion-proof

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-25 .. 55°C

Power loss

4.5W

Flush-mounted installation

Number of poles (total)

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated impulse withstand voltage Uimp

4kV