Aleta.hr
Main Product Image

2CDS273347R0487 | SU203MR-K20

Code: 2003264

ManufacturerABB
Catalog number2CDS273347R0487
EAN code4016779958493

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles3
Rated voltage400V
Release characteristicK
Rated insulation voltage Ui440V
Built-in depth69mm
Rated current20A
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Number of poles (total)3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Power loss7.5W
Rated impulse withstand voltage Uimp4kV
Voltage typeOther
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Flush-mounted installationNo
Degree of protection (IP)IP20
Connectable conductor cross section solid-core0.75 - 35mm²
Explosion-proofNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Width in number of modular spacings3.0
Additional equipment possibleYes
Ambient temperature during operating-25 - 55°C
Pollution degree3
Concurrently switching neutral conductorNo
Over voltage category3

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273347R0487 | SU203MR-K20

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

3

Rated voltage

400V

Release characteristic

K

Rated insulation voltage Ui

440V

Built-in depth

69mm

Rated current

20A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Power loss

7.5W

Rated impulse withstand voltage Uimp

4kV

Voltage type

Other

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Flush-mounted installation

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0.75 .. 35mm²

Explosion-proof

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Width in number of modular spacings

3.0

Additional equipment possible

Ambient temperature during operating

-25 .. 55°C

Pollution degree

3

Concurrently switching neutral conductor

Over voltage category

3

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.