Technical specifications

Built-in depth69mm
Release characteristicD
Number of poles (total)3
Rated voltage400V
Rated current1A
Rated impulse withstand voltage Uimp4kV
Number of protected poles3
Rated insulation voltage Ui440V
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Frequency50 - 60Hz
Current limiting class3
Power loss4.2W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Flush-mounted installationNo
Over voltage category3
Ambient temperature during operating-40 - 70°C
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core0.75 - 35mm²
Degree of protection (IP)IP20
Additional equipment possibleYes
Pollution degree3
Width in number of modular spacings3.0
Explosion-proofNo
Connectable conductor cross section multi-wired0.75 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273445R0011 | S203MT-D1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Release characteristic

D

Number of poles (total)

3

Rated voltage

400V

Rated current

1A

Rated impulse withstand voltage Uimp

4kV

Number of protected poles

3

Rated insulation voltage Ui

440V

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Frequency

50 .. 60Hz

Current limiting class

3

Power loss

4.2W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Flush-mounted installation

Over voltage category

3

Ambient temperature during operating

-40 .. 70°C

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

0.75 .. 35mm²

Degree of protection (IP)

IP20

Additional equipment possible

Pollution degree

3

Width in number of modular spacings

3.0

Explosion-proof

Connectable conductor cross section multi-wired

0.75 .. 25mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.