Aleta.hr
Main Product Image

2CDS273445R0085 | S203MT-B8

Code: 2003293

ManufacturerRAZNO
Catalog number2CDS273445R0085
Type
EAN code4016779122689

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

3

Release characteristic

B

Built-in depth

69mm

Rated insulation voltage Ui

440V

Rated current

8A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Number of protected poles

3

Rated voltage

400V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Power loss

4.5W

Frequency

50 - 60Hz

Current limiting class

3

Rated impulse withstand voltage Uimp

4kV

Width in number of modular spacings

3.0

Flush-mounted installation

No

Over voltage category

3

Concurrently switching neutral conductor

No

Degree of protection (IP)

IP20

Additional equipment possible

Yes

Pollution degree

3

Connectable conductor cross section multi-wired

0.75 - 25mm²

Connectable conductor cross section solid-core

0.75 - 35mm²

Ambient temperature during operating

-40 - 70°C

Explosion-proof

No

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CDS273445R0085 | S203MT-B8

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

3

Release characteristic

B

Built-in depth

69mm

Rated insulation voltage Ui

440V

Rated current

8A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Number of protected poles

3

Rated voltage

400V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Power loss

4.5W

Frequency

50 .. 60Hz

Current limiting class

3

Rated impulse withstand voltage Uimp

4kV

Width in number of modular spacings

3.0

Flush-mounted installation

Over voltage category

3

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Additional equipment possible

Pollution degree

3

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Connectable conductor cross section solid-core

0.75 .. 35mm²

Ambient temperature during operating

-40 .. 70°C

Explosion-proof

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.