Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Pollution degree3
Release characteristicB
Frequency50 - 60Hz
Voltage typeOther
Rated voltage400V
Over voltage category3
Explosion-proofNo
Connectable conductor cross section solid-core0.75 - 35mm²
Power loss4.5W
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0.75 - 25mm²
Width in number of modular spacings3.0
Built-in depth69mm
Number of protected poles3
Current limiting class3
Concurrently switching neutral conductorNo
Rated current8A
Number of poles (total)3
Additional equipment possibleYes
Flush-mounted installationNo
Ambient temperature during operating-40 - 70°C
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273445R0085 | S203MT-B8

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Pollution degree

3

Release characteristic

B

Frequency

50 .. 60Hz

Voltage type

Other

Rated voltage

400V

Over voltage category

3

Explosion-proof

Connectable conductor cross section solid-core

0.75 .. 35mm²

Power loss

4.5W

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Width in number of modular spacings

3.0

Built-in depth

69mm

Number of protected poles

3

Current limiting class

3

Concurrently switching neutral conductor

Rated current

8A

Number of poles (total)

3

Additional equipment possible

Flush-mounted installation

Ambient temperature during operating

-40 .. 70°C

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.