Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current0.3A
Frequency50 - 60Hz
Release characteristicK
Voltage typeOther
Built-in depth69mm
Rated voltage440V
Number of protected poles3
Current limiting class3
Over voltage category3
Degree of protection (IP)IP20
Explosion-proofNo
Width in number of modular spacings3.0
Pollution degree3
Rated insulation voltage Ui440V
Power loss5.1W
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Ambient temperature during operating-40 - 70°C
Connectable conductor cross section multi-wired0.75 - 25mm²
Concurrently switching neutral conductorNo
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Number of poles (total)3
Connectable conductor cross section solid-core0.75 - 35mm²
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273445R0117 | S203MT-K0,3

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

0.3A

Frequency

50 .. 60Hz

Release characteristic

K

Voltage type

Other

Built-in depth

69mm

Rated voltage

440V

Number of protected poles

3

Current limiting class

3

Over voltage category

3

Degree of protection (IP)

IP20

Explosion-proof

Width in number of modular spacings

3.0

Pollution degree

3

Rated insulation voltage Ui

440V

Power loss

5.1W

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Ambient temperature during operating

-40 .. 70°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Concurrently switching neutral conductor

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Number of poles (total)

3

Connectable conductor cross section solid-core

0.75 .. 35mm²

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.