Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicC
Rated voltage400V
Rated insulation voltage Ui440V
Rated impulse withstand voltage Uimp4kV
Rated current35A
Number of poles (total)3
Number of protected poles3
Built-in depth69mm
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Power loss-W
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Current limiting class3
Pollution degree3
Additional equipment possibleYes
Width in number of modular spacings3.0
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0.75 - 25mm²
Over voltage category3
Ambient temperature during operating-40 - 70°C
Flush-mounted installationNo
Connectable conductor cross section solid-core0.75 - 35mm²
Explosion-proofNo
Concurrently switching neutral conductorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273445R0354 | S203MT-C35

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

C

Rated voltage

400V

Rated insulation voltage Ui

440V

Rated impulse withstand voltage Uimp

4kV

Rated current

35A

Number of poles (total)

3

Number of protected poles

3

Built-in depth

69mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Power loss

-W

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Current limiting class

3

Pollution degree

3

Additional equipment possible

Width in number of modular spacings

3.0

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Over voltage category

3

Ambient temperature during operating

-40 .. 70°C

Flush-mounted installation

Connectable conductor cross section solid-core

0.75 .. 35mm²

Explosion-proof

Concurrently switching neutral conductor

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.