  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Number of poles (total)3
Release characteristicZ
Rated current10A
Number of protected poles3
Rated voltage440V
Voltage typeOther
Rated impulse withstand voltage Uimp4kV
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Power loss8.1W
Degree of protection (IP)IP20
Width in number of modular spacings3.0
Pollution degree3
Connectable conductor cross section multi-wired0.75 - 25mm²
Additional equipment possibleYes
Ambient temperature during operating-40 - 70°C
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core0.75 - 35mm²
Explosion-proofNo
Over voltage category3
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273445R0428 | S203MT-Z10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Number of poles (total)

3

Release characteristic

Z

Rated current

10A

Number of protected poles

3

Rated voltage

440V

Voltage type

Other

Rated impulse withstand voltage Uimp

4kV

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Power loss

8.1W

Degree of protection (IP)

IP20

Width in number of modular spacings

3.0

Pollution degree

3

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Additional equipment possible

Ambient temperature during operating

-40 .. 70°C

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

0.75 .. 35mm²

Explosion-proof

Over voltage category

3

Flush-mounted installation