Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeOther
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Number of poles (total)3
Rated voltage440V
Release characteristicK
Built-in depth69mm
Rated current13A
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui440V
Power loss7.2W
Number of protected poles3
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Over voltage category3
Pollution degree3
Connectable conductor cross section solid-core0.75 - 35mm²
Flush-mounted installationNo
Width in number of modular spacings3.0
Concurrently switching neutral conductorNo
Explosion-proofNo
Degree of protection (IP)IP20
Additional equipment possibleYes
Connectable conductor cross section multi-wired0.75 - 25mm²
Ambient temperature during operating-40 - 70°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273445R0447 | S203MT-K13

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Number of poles (total)

3

Rated voltage

440V

Release characteristic

K

Built-in depth

69mm

Rated current

13A

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Power loss

7.2W

Number of protected poles

3

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Over voltage category

3

Pollution degree

3

Connectable conductor cross section solid-core

0.75 .. 35mm²

Flush-mounted installation

Width in number of modular spacings

3.0

Concurrently switching neutral conductor

Explosion-proof

Degree of protection (IP)

IP20

Additional equipment possible

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-40 .. 70°C

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.