Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated impulse withstand voltage Uimp4kV
Power loss-W
Rated current60A
Built-in depth69mm
Number of poles (total)3
Frequency50 - 60Hz
Rated voltage400V
Rated insulation voltage Ui440V
Release characteristicC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Voltage typeOther
Current limiting class3
Number of protected poles3
Width in number of modular spacings3.0
Concurrently switching neutral conductorNo
Over voltage category3
Additional equipment possibleYes
Pollution degree3
Connectable conductor cross section solid-core0.75 - 35mm²
Flush-mounted installationNo
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0.75 - 25mm²
Ambient temperature during operating-40 - 70°C
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273445R0604 | S203MT-C60

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated impulse withstand voltage Uimp

4kV

Power loss

-W

Rated current

60A

Built-in depth

69mm

Number of poles (total)

3

Frequency

50 .. 60Hz

Rated voltage

400V

Rated insulation voltage Ui

440V

Release characteristic

C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Voltage type

Other

Current limiting class

3

Number of protected poles

3

Width in number of modular spacings

3.0

Concurrently switching neutral conductor

Over voltage category

3

Additional equipment possible

Pollution degree

3

Connectable conductor cross section solid-core

0.75 .. 35mm²

Flush-mounted installation

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-40 .. 70°C

Explosion-proof