Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicB
Built-in depth69mm
Rated insulation voltage Ui440V
Rated impulse withstand voltage Uimp4kV
Rated voltage400V
Number of protected poles3
Voltage typeOther
Power loss14.4W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Number of poles (total)3
Current limiting class3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated current63A
Frequency50 - 60Hz
Concurrently switching neutral conductorNo
Over voltage category3
Flush-mounted installationNo
Explosion-proofNo
Connectable conductor cross section solid-core0.75 - 35mm²
Degree of protection (IP)IP20
Additional equipment possibleYes
Connectable conductor cross section multi-wired0.75 - 25mm²
Ambient temperature during operating-40 - 70°C
Pollution degree3
Width in number of modular spacings3.0
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273445R0635 | S203MT-B63

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

B

Built-in depth

69mm

Rated insulation voltage Ui

440V

Rated impulse withstand voltage Uimp

4kV

Rated voltage

400V

Number of protected poles

3

Voltage type

Other

Power loss

14.4W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Number of poles (total)

3

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated current

63A

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Over voltage category

3

Flush-mounted installation

Explosion-proof

Connectable conductor cross section solid-core

0.75 .. 35mm²

Degree of protection (IP)

IP20

Additional equipment possible

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-40 .. 70°C

Pollution degree

3

Width in number of modular spacings

3.0

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.