Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current3A
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated voltage400V
Rated impulse withstand voltage Uimp4kV
Power loss5.2W
Release characteristicC
Voltage typeOther
Built-in depth69mm
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Number of poles (total)4
Current limiting class3
Number of protected poles3
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated insulation voltage Ui440V
Additional equipment possibleYes
Degree of protection (IP)IP20
Over voltage category3
Pollution degree3
Concurrently switching neutral conductorYes
Flush-mounted installationNo
Connectable conductor cross section solid-core0.75 - 35mm²
Width in number of modular spacings4.0
Ambient temperature during operating-40 - 70°C
Explosion-proofNo
Connectable conductor cross section multi-wired0.75 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273446R0034 | S203MT-C3NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

3A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated voltage

400V

Rated impulse withstand voltage Uimp

4kV

Power loss

5.2W

Release characteristic

C

Voltage type

Other

Built-in depth

69mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Number of poles (total)

4

Current limiting class

3

Number of protected poles

3

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated insulation voltage Ui

440V

Additional equipment possible

Degree of protection (IP)

IP20

Over voltage category

3

Pollution degree

3

Concurrently switching neutral conductor

Flush-mounted installation

Connectable conductor cross section solid-core

0.75 .. 35mm²

Width in number of modular spacings

4.0

Ambient temperature during operating

-40 .. 70°C

Explosion-proof

Connectable conductor cross section multi-wired

0.75 .. 25mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.