Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Release characteristicC
Rated current6A
Rated insulation voltage Ui440V
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Number of protected poles3
Rated impulse withstand voltage Uimp4kV
Rated voltage400V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Voltage typeOther
Frequency50 - 60Hz
Power loss8W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Current limiting class3
Additional equipment possibleYes
Over voltage category3
Degree of protection (IP)IP20
Flush-mounted installationNo
Concurrently switching neutral conductorYes
Width in number of modular spacings4.0
Connectable conductor cross section multi-wired0.75 - 25mm²
Ambient temperature during operating-40 - 70°C
Pollution degree3
Explosion-proofNo
Connectable conductor cross section solid-core0.75 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273446R0064 | S203MT-C6NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Release characteristic

C

Rated current

6A

Rated insulation voltage Ui

440V

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Number of protected poles

3

Rated impulse withstand voltage Uimp

4kV

Rated voltage

400V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Voltage type

Other

Frequency

50 .. 60Hz

Power loss

8W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Current limiting class

3

Additional equipment possible

Over voltage category

3

Degree of protection (IP)

IP20

Flush-mounted installation

Concurrently switching neutral conductor

Width in number of modular spacings

4.0

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-40 .. 70°C

Pollution degree

3

Explosion-proof

Connectable conductor cross section solid-core

0.75 .. 35mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.