  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Pollution degree3
Rated voltage400V
Over voltage category3
Explosion-proofNo
Rated current25A
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
Degree of protection (IP)IP20
Frequency50 - 60Hz
Width in number of modular spacings4.0
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Release characteristicD
Current limiting class3
Flush-mounted installationNo
Ambient temperature during operating-40 - 70°C
Power loss12.8W
Voltage typeOther
Number of protected poles3
Number of poles (total)4
Concurrently switching neutral conductorYes
Additional equipment possibleYes
Rated insulation voltage Ui440V
Built-in depth69mm
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273446R0251 | S203MT-D25NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Pollution degree

3

Rated voltage

400V

Over voltage category

3

Explosion-proof

Rated current

25A

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Degree of protection (IP)

IP20

Frequency

50 .. 60Hz

Width in number of modular spacings

4.0

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Release characteristic

D

Current limiting class

3

Flush-mounted installation

Ambient temperature during operating

-40 .. 70°C

Power loss

12.8W

Voltage type

Other

Number of protected poles

3

Number of poles (total)

4

Concurrently switching neutral conductor

Additional equipment possible

Rated insulation voltage Ui

440V

Built-in depth

69mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.