Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated impulse withstand voltage Uimp4kV
Number of protected poles3
Voltage typeOther
Number of poles (total)4
Rated insulation voltage Ui440V
Rated voltage440V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated current3A
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Power loss4.8W
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Frequency50 - 60Hz
Built-in depth69mm
Release characteristicK
Width in number of modular spacings4.0
Pollution degree3
Connectable conductor cross section multi-wired0.75 - 25mm²
Over voltage category3
Additional equipment possibleYes
Degree of protection (IP)IP20
Connectable conductor cross section solid-core0.75 - 35mm²
Flush-mounted installationNo
Explosion-proofNo
Concurrently switching neutral conductorYes
Ambient temperature during operating-40 - 70°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273446R0317 | S203MT-K3NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated impulse withstand voltage Uimp

4kV

Number of protected poles

3

Voltage type

Other

Number of poles (total)

4

Rated insulation voltage Ui

440V

Rated voltage

440V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated current

3A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Power loss

4.8W

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Frequency

50 .. 60Hz

Built-in depth

69mm

Release characteristic

K

Width in number of modular spacings

4.0

Pollution degree

3

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Over voltage category

3

Additional equipment possible

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0.75 .. 35mm²

Flush-mounted installation

Explosion-proof

Concurrently switching neutral conductor

Ambient temperature during operating

-40 .. 70°C