Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicZ
Built-in depth69mm
Number of protected poles3
Rated current15A
Number of poles (total)4
Rated insulation voltage Ui440V
Frequency50 - 60Hz
Rated voltage440V
Rated impulse withstand voltage Uimp4kV
Voltage typeOther
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Power loss12W
Current limiting class3
Concurrently switching neutral conductorYes
Additional equipment possibleYes
Over voltage category3
Pollution degree3
Width in number of modular spacings4.0
Degree of protection (IP)IP20
Ambient temperature during operating-40 - 70°C
Explosion-proofNo
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273446R0458 | S203MT-Z15NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

Z

Built-in depth

69mm

Number of protected poles

3

Rated current

15A

Number of poles (total)

4

Rated insulation voltage Ui

440V

Frequency

50 .. 60Hz

Rated voltage

440V

Rated impulse withstand voltage Uimp

4kV

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Power loss

12W

Current limiting class

3

Concurrently switching neutral conductor

Additional equipment possible

Over voltage category

3

Pollution degree

3

Width in number of modular spacings

4.0

Degree of protection (IP)

IP20

Ambient temperature during operating

-40 .. 70°C

Explosion-proof

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Flush-mounted installation