Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency50 - 60Hz
Rated current20A
Built-in depth69mm
Current limiting class3
Pollution degree3
Rated voltage440V
Voltage typeOther
Rated insulation voltage Ui440V
Over voltage category3
Release characteristicB
Width in number of modular spacings3.0
Degree of protection (IP)IP20
Power loss9.1W
Explosion-proofNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Additional equipment possibleYes
Number of poles (total)3
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
Ambient temperature during operating-40 - 75°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Flush-mounted installationNo
Rated impulse withstand voltage Uimp4kV
Concurrently switching neutral conductorNo
Number of protected poles3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273447R0205 | S203MTR-B20

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency

50 .. 60Hz

Rated current

20A

Built-in depth

69mm

Current limiting class

3

Pollution degree

3

Rated voltage

440V

Voltage type

Other

Rated insulation voltage Ui

440V

Over voltage category

3

Release characteristic

B

Width in number of modular spacings

3.0

Degree of protection (IP)

IP20

Power loss

9.1W

Explosion-proof

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Additional equipment possible

Number of poles (total)

3

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-40 .. 75°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Flush-mounted installation

Rated impulse withstand voltage Uimp

4kV

Concurrently switching neutral conductor

Number of protected poles

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.