Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicK
Voltage typeOther
Rated voltage440V
Frequency50 - 60Hz
Rated current50A
Built-in depth69mm
Pollution degree3
Power loss10.6W
Explosion-proofNo
Number of protected poles3
Degree of protection (IP)IP20
Width in number of modular spacings3.0
Over voltage category3
Rated insulation voltage Ui440V
Current limiting class3
Concurrently switching neutral conductorNo
Number of poles (total)3
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Connectable conductor cross section solid-core0.75 - 35mm²
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Connectable conductor cross section multi-wired0.75 - 25mm²
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Ambient temperature during operating-40 - 75°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273447R0577 | S203MTR-K50

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

K

Voltage type

Other

Rated voltage

440V

Frequency

50 .. 60Hz

Rated current

50A

Built-in depth

69mm

Pollution degree

3

Power loss

10.6W

Explosion-proof

Number of protected poles

3

Degree of protection (IP)

IP20

Width in number of modular spacings

3.0

Over voltage category

3

Rated insulation voltage Ui

440V

Current limiting class

3

Concurrently switching neutral conductor

Number of poles (total)

3

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Connectable conductor cross section solid-core

0.75 .. 35mm²

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Ambient temperature during operating

-40 .. 75°C

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.