Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Release characteristicK
Number of protected poles4
Rated current0.3A
Rated voltage440V
Rated insulation voltage Ui440V
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Power loss6.8W
Voltage typeOther
Current limiting class3
Over voltage category3
Additional equipment possibleYes
Flush-mounted installationNo
Width in number of modular spacings4.0
Degree of protection (IP)IP20
Ambient temperature during operating-40 - 70°C
Concurrently switching neutral conductorNo
Pollution degree3
Explosion-proofNo
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS274445R0117 | S204MT-K0,3

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Release characteristic

K

Number of protected poles

4

Rated current

0.3A

Rated voltage

440V

Rated insulation voltage Ui

440V

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Power loss

6.8W

Voltage type

Other

Current limiting class

3

Over voltage category

3

Additional equipment possible

Flush-mounted installation

Width in number of modular spacings

4.0

Degree of protection (IP)

IP20

Ambient temperature during operating

-40 .. 70°C

Concurrently switching neutral conductor

Pollution degree

3

Explosion-proof

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.