Aleta.hr
Main Product Image

2CDS274445R0278 | S204MT-Z2

Code: 2003604

ManufacturerRAZNO
Catalog number2CDS274445R0278
Type
EAN code4016779128384

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

4

Built-in depth

69mm

Release characteristic

Z

Rated impulse withstand voltage Uimp

4kV

Rated voltage

440V

Rated insulation voltage Ui

440V

Frequency

50 - 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated current

2A

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Power loss

10W

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Number of protected poles

4

Flush-mounted installation

No

Connectable conductor cross section multi-wired

0.75 - 25mm²

Connectable conductor cross section solid-core

0.75 - 35mm²

Pollution degree

3

Degree of protection (IP)

IP20

Over voltage category

3

Concurrently switching neutral conductor

No

Width in number of modular spacings

4.0

Explosion-proof

No

Additional equipment possible

Yes

Ambient temperature during operating

-40 - 70°C

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CDS274445R0278 | S204MT-Z2

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

4

Built-in depth

69mm

Release characteristic

Z

Rated impulse withstand voltage Uimp

4kV

Rated voltage

440V

Rated insulation voltage Ui

440V

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated current

2A

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Power loss

10W

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Number of protected poles

4

Flush-mounted installation

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Connectable conductor cross section solid-core

0.75 .. 35mm²

Pollution degree

3

Degree of protection (IP)

IP20

Over voltage category

3

Concurrently switching neutral conductor

Width in number of modular spacings

4.0

Explosion-proof

Additional equipment possible

Ambient temperature during operating

-40 .. 70°C

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.