Built-in depth69mm
Rated voltage400V
Voltage typeOther
Number of poles (total)4
Release characteristicC
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Power loss-W
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated current35A
Number of protected poles4
Width in number of modular spacings4.0
Degree of protection (IP)IP20
Additional equipment possibleYes
Ambient temperature during operating-40 - 70°C
Over voltage category3
Concurrently switching neutral conductorNo
Pollution degree3
Flush-mounted installationNo
Connectable conductor cross section solid-core0.75 - 35mm²
Explosion-proofNo
Connectable conductor cross section multi-wired0.75 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS274445R0354 | S204MT-C35

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Rated voltage

400V

Voltage type

Other

Number of poles (total)

4

Release characteristic

C

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Power loss

-W

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated current

35A

Number of protected poles

4

Width in number of modular spacings

4.0

Degree of protection (IP)

IP20

Additional equipment possible

Ambient temperature during operating

-40 .. 70°C

Over voltage category

3

Concurrently switching neutral conductor

Pollution degree

3

Flush-mounted installation

Connectable conductor cross section solid-core

0.75 .. 35mm²

Explosion-proof

Connectable conductor cross section multi-wired

0.75 .. 25mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.