Technical specifications

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated current2A
Number of protected poles4
Number of poles (total)4
Power loss5.4W
Built-in depth69mm
Rated insulation voltage Ui440V
Rated voltage440V
Release characteristicK
Voltage typeOther
Current limiting class3
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Concurrently switching neutral conductorNo
Pollution degree3
Degree of protection (IP)IP20
Additional equipment possibleYes
Width in number of modular spacings4.0
Ambient temperature during operating-40 - 75°C
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
Explosion-proofNo
Over voltage category3
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS274447R0277 | S204MTR-K2

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated current

2A

Number of protected poles

4

Number of poles (total)

4

Power loss

5.4W

Built-in depth

69mm

Rated insulation voltage Ui

440V

Rated voltage

440V

Release characteristic

K

Voltage type

Other

Current limiting class

3

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Concurrently switching neutral conductor

Pollution degree

3

Degree of protection (IP)

IP20

Additional equipment possible

Width in number of modular spacings

4.0

Ambient temperature during operating

-40 .. 75°C

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Explosion-proof

Over voltage category

3

Flush-mounted installation