Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Over voltage category3
Explosion-proofNo
Power loss9.6W
Rated current10A
Degree of protection (IP)IP20
Rated voltage440V
Pollution degree3
Voltage typeOther
Number of protected poles4
Release characteristicB
Width in number of modular spacings4.0
Current limiting class3
Built-in depth69mm
Frequency50 - 60Hz
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Flush-mounted installationNo
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Ambient temperature during operating-40 - 75°C
Additional equipment possibleYes
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
Rated insulation voltage Ui440V
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS274565R0105 | S204MTR-B10 DC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Over voltage category

3

Explosion-proof

Power loss

9.6W

Rated current

10A

Degree of protection (IP)

IP20

Rated voltage

440V

Pollution degree

3

Voltage type

Other

Number of protected poles

4

Release characteristic

B

Width in number of modular spacings

4.0

Current limiting class

3

Built-in depth

69mm

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Flush-mounted installation

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Ambient temperature during operating

-40 .. 75°C

Additional equipment possible

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Rated insulation voltage Ui

440V

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA