Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Rated current20A
Voltage typeOther
Rated voltage440V
Release characteristicB
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Current limiting class3
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Number of protected poles4
Additional equipment possibleYes
Ambient temperature during operating-40 - 75°C
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
Flush-mounted installationNo
Number of poles (total)4
Explosion-proofNo
Over voltage category3
Pollution degree3
Degree of protection (IP)IP20
Width in number of modular spacings4.0
Rated impulse withstand voltage Uimp4kV
Concurrently switching neutral conductorNo
Power loss12.1W
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS274565R0205 | S204MTR-B20 DC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Rated current

20A

Voltage type

Other

Rated voltage

440V

Release characteristic

B

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Current limiting class

3

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Number of protected poles

4

Additional equipment possible

Ambient temperature during operating

-40 .. 75°C

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Flush-mounted installation

Number of poles (total)

4

Explosion-proof

Over voltage category

3

Pollution degree

3

Degree of protection (IP)

IP20

Width in number of modular spacings

4.0

Rated impulse withstand voltage Uimp

4kV

Concurrently switching neutral conductor

Power loss

12.1W

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.