Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage440V
Number of poles (total)4
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Release characteristicK
Power loss5.2W
Rated current1A
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Built-in depth69mm
Rated impulse withstand voltage Uimp4kV
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated insulation voltage Ui440V
Current limiting class3
Number of protected poles4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core0.75 - 35mm²
Explosion-proofNo
Width in number of modular spacings4.0
Additional equipment possibleYes
Over voltage category3
Degree of protection (IP)IP20
Pollution degree3
Ambient temperature during operating-40 - 75°C
Connectable conductor cross section multi-wired0.75 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS274565R0217 | S204MTR-K1 DC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

440V

Number of poles (total)

4

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Release characteristic

K

Power loss

5.2W

Rated current

1A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Built-in depth

69mm

Rated impulse withstand voltage Uimp

4kV

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated insulation voltage Ui

440V

Current limiting class

3

Number of protected poles

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Flush-mounted installation

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

0.75 .. 35mm²

Explosion-proof

Width in number of modular spacings

4.0

Additional equipment possible

Over voltage category

3

Degree of protection (IP)

IP20

Pollution degree

3

Ambient temperature during operating

-40 .. 75°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.