Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui440V
Rated current1.6A
Rated impulse withstand voltage Uimp4kV
Number of poles (total)4
Built-in depth69mm
Release characteristicK
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Power loss5.1W
Current limiting class3
Frequency50 - 60Hz
Number of protected poles4
Rated voltage440V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Voltage typeOther
Explosion-proofNo
Pollution degree3
Flush-mounted installationNo
Over voltage category3
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Width in number of modular spacings4.0
Additional equipment possibleYes
Ambient temperature during operating-40 - 75°C
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS274565R0257 | S204MTR-K1,6 DC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

440V

Rated current

1.6A

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

4

Built-in depth

69mm

Release characteristic

K

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Power loss

5.1W

Current limiting class

3

Frequency

50 .. 60Hz

Number of protected poles

4

Rated voltage

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Voltage type

Other

Explosion-proof

Pollution degree

3

Flush-mounted installation

Over voltage category

3

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Width in number of modular spacings

4.0

Additional equipment possible

Ambient temperature during operating

-40 .. 75°C

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.