Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current3A
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Number of protected poles4
Built-in depth69mm
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated insulation voltage Ui440V
Release characteristicZ
Voltage typeOther
Rated impulse withstand voltage Uimp4kV
Power loss9.9W
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated voltage440V
Over voltage category3
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Degree of protection (IP)IP20
Width in number of modular spacings4.0
Explosion-proofNo
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
Pollution degree3
Ambient temperature during operating-40 - 75°C
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS274565R0318 | S204MTR-Z3 DC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

3A

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Number of protected poles

4

Built-in depth

69mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated insulation voltage Ui

440V

Release characteristic

Z

Voltage type

Other

Rated impulse withstand voltage Uimp

4kV

Power loss

9.9W

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated voltage

440V

Over voltage category

3

Concurrently switching neutral conductor

Additional equipment possible

Degree of protection (IP)

IP20

Width in number of modular spacings

4.0

Explosion-proof

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Pollution degree

3

Ambient temperature during operating

-40 .. 75°C

Flush-mounted installation

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.