Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Release characteristicK
Number of poles (total)4
Number of protected poles4
Rated insulation voltage Ui440V
Rated voltage440V
Rated current13A
Rated impulse withstand voltage Uimp4kV
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Power loss8.2W
Current limiting class3
Concurrently switching neutral conductorNo
Over voltage category3
Pollution degree3
Additional equipment possibleYes
Width in number of modular spacings4.0
Flush-mounted installationNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Degree of protection (IP)IP20
Ambient temperature during operating-40 - 75°C
Explosion-proofNo
Connectable conductor cross section solid-core0.75 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS274565R0447 | S204MTR-K13 DC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Release characteristic

K

Number of poles (total)

4

Number of protected poles

4

Rated insulation voltage Ui

440V

Rated voltage

440V

Rated current

13A

Rated impulse withstand voltage Uimp

4kV

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Power loss

8.2W

Current limiting class

3

Concurrently switching neutral conductor

Over voltage category

3

Pollution degree

3

Additional equipment possible

Width in number of modular spacings

4.0

Flush-mounted installation

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Degree of protection (IP)

IP20

Ambient temperature during operating

-40 .. 75°C

Explosion-proof

Connectable conductor cross section solid-core

0.75 .. 35mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.