Technical specifications

Number of poles (total)2
Rated insulation voltage Ui500V
Number of protected poles1
Rated short-circuit breaking capacity according to EN 610096kA
Rated current13A
Rated impulse withstand voltage Uimp4kV
Current limiting class3
Leakage current typeAC
Power loss2.47W
Rated fault current0.03A
Rated voltage240V
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Disconnection characteristicUndelayed
Voltage typeAC
Surge current capacity-kA
Rated short-circuit breaking capacity according to IEC 60947-26kA
Concurrently switching neutral conductorYes
Pollution degree2
Frequency50/60 Hz
With interlocking deviceNo
Release characteristicB
Anti-nuisance tripping versionNo
Over voltage category3
Flush-mounted installationNo
Width in number of modular spacings1
Ambient temperature during operating-25 - 55°C
Degree of protection (IP)IP20
Connectable conductor cross section solid-core1.5 - 16mm²
Built-in depth17.6mm
Connectable conductor cross section multi-wired1.5 - 16mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR255063U1135 | DS301C B13 AC30

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

2

Rated insulation voltage Ui

500V

Number of protected poles

1

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated current

13A

Rated impulse withstand voltage Uimp

4kV

Current limiting class

3

Leakage current type

AC

Power loss

2.47W

Rated fault current

0.03A

Rated voltage

240V

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Disconnection characteristic

Undelayed

Voltage type

AC

Surge current capacity

-kA

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Concurrently switching neutral conductor

Pollution degree

2

Frequency

50/60 Hz

With interlocking device

Release characteristic

B

Anti-nuisance tripping version

Over voltage category

3

Flush-mounted installation

Width in number of modular spacings

1

Ambient temperature during operating

-25 .. 55°C

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

1.5 .. 16mm²

Built-in depth

17.6mm

Connectable conductor cross section multi-wired

1.5 .. 16mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.