Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Built-in depth17.6mm
Rated voltage240V
Voltage typeAC
Release characteristicB
Rated current16A
Rated insulation voltage Ui500V
Rated fault current0.03A
Number of protected poles1
Leakage current typeAC
Degree of protection (IP)IP20
Frequency50/60 Hz
Current limiting class3
Surge current capacity-kA
Pollution degree2
Width in number of modular spacings1
Over voltage category3
Power loss2.83W
Rated short-circuit breaking capacity according to IEC 60947-26kA
With interlocking deviceNo
Concurrently switching neutral conductorYes
Connectable conductor cross section solid-core1.5 - 16mm²
Connectable conductor cross section multi-wired1.5 - 16mm²
Ambient temperature during operating-25 - 55°C
Number of poles (total)2
Flush-mounted installationNo
Anti-nuisance tripping versionNo
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to EN 610096kA
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR255063U1165 | DS301C B16 AC30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

17.6mm

Rated voltage

240V

Voltage type

AC

Release characteristic

B

Rated current

16A

Rated insulation voltage Ui

500V

Rated fault current

0.03A

Number of protected poles

1

Leakage current type

AC

Degree of protection (IP)

IP20

Frequency

50/60 Hz

Current limiting class

3

Surge current capacity

-kA

Pollution degree

2

Width in number of modular spacings

1

Over voltage category

3

Power loss

2.83W

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

With interlocking device

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

1.5 .. 16mm²

Connectable conductor cross section multi-wired

1.5 .. 16mm²

Ambient temperature during operating

-25 .. 55°C

Number of poles (total)

2

Flush-mounted installation

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to EN 61009

6kA

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.