  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Release characteristicB
Rated voltage240V
Voltage typeAC
Built-in depth68.9mm
Rated current16A
Pollution degree2
Rated insulation voltage Ui500V
Rated fault current0.03A
Over voltage category3
Current limiting class3
Width in number of modular spacings1
Surge current capacity0.25kA
Power loss3.8W
Leakage current typeA
Degree of protection (IP)IP20
Rated short-circuit breaking capacity according to IEC 60947-2-kA
Frequency50/60 Hz
Number of protected poles1
With interlocking deviceYes
Connectable conductor cross section multi-wired1 - 16mm²
Connectable conductor cross section solid-core1 - 25mm²
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Anti-nuisance tripping versionNo
Flush-mounted installationNo
Number of poles (total)2
Disconnection characteristicUndelayed
Rated impulse withstand voltage Uimp4kV
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity according to EN 610096kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR255151R1165 | DSE201 B16 A30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

B

Rated voltage

240V

Voltage type

AC

Built-in depth

68.9mm

Rated current

16A

Pollution degree

2

Rated insulation voltage Ui

500V

Rated fault current

0.03A

Over voltage category

3

Current limiting class

3

Width in number of modular spacings

1

Surge current capacity

0.25kA

Power loss

3.8W

Leakage current type

A

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity according to IEC 60947-2

-kA

Frequency

50/60 Hz

Number of protected poles

1

With interlocking device

Connectable conductor cross section multi-wired

1 .. 16mm²

Connectable conductor cross section solid-core

1 .. 25mm²

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Anti-nuisance tripping version

Flush-mounted installation

Number of poles (total)

2

Disconnection characteristic

Undelayed

Rated impulse withstand voltage Uimp

4kV

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity according to EN 61009

6kA