Aleta.hr
Main Product Image

2CSR255151R1205 | DSE201 B20 A30

Code: 2004217

ManufacturerABB
Catalog number2CSR255151R1205
EAN code8012542658429

















Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)2
Number of protected poles1
Rated voltage240V
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Rated current20A
Rated fault current0.03A
Leakage current typeA
Current limiting class3
Power loss5.5W
Rated short-circuit breaking capacity according to EN 610096kA
Rated short-circuit breaking capacity according to IEC 60947-2-kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Disconnection characteristicUndelayed
Surge current capacity0.25kA
Voltage typeAC
Frequency50/60 Hz
Release characteristicB
Concurrently switching neutral conductorNo
With interlocking deviceYes
Over voltage category3
Pollution degree2
Ambient temperature during operating-25 - 55°C
Width in number of modular spacings1
Built-in depth68.9mm
Flush-mounted installationNo
Anti-nuisance tripping versionNo
Degree of protection (IP)IP20
Connectable conductor cross section solid-core1 - 25mm²
Connectable conductor cross section multi-wired1 - 16mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR255151R1205 | DSE201 B20 A30

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

2

Number of protected poles

1

Rated voltage

240V

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated current

20A

Rated fault current

0.03A

Leakage current type

A

Current limiting class

3

Power loss

5.5W

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated short-circuit breaking capacity according to IEC 60947-2

-kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Disconnection characteristic

Undelayed

Surge current capacity

0.25kA

Voltage type

AC

Frequency

50/60 Hz

Release characteristic

B

Concurrently switching neutral conductor

With interlocking device

Over voltage category

3

Pollution degree

2

Ambient temperature during operating

-25 .. 55°C

Width in number of modular spacings

1

Built-in depth

68.9mm

Flush-mounted installation

Anti-nuisance tripping version

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

1 .. 25mm²

Connectable conductor cross section multi-wired

1 .. 16mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.