Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated current6A
Built-in depth17.6mm
Voltage typeAC
Surge current capacity-kA
Release characteristicC
Rated insulation voltage Ui500V
Leakage current typeA
Current limiting class3
Rated fault current0.03A
Rated voltage240V
Over voltage category3
Pollution degree2
Power loss1.56W
Number of poles (total)2
Degree of protection (IP)IP20
Number of protected poles1
Width in number of modular spacings1
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to IEC 60947-26kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Ambient temperature during operating-25 - 55°C
Concurrently switching neutral conductorYes
Flush-mounted installationNo
Connectable conductor cross section solid-core1.5 - 16mm²
Anti-nuisance tripping versionNo
Frequency50/60 Hz
Connectable conductor cross section multi-wired1.5 - 16mm²
With interlocking deviceNo
Rated short-circuit breaking capacity according to EN 610096kA
Disconnection characteristicUndelayed
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR255164R1064 | DS301CT C6 A30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated current

6A

Built-in depth

17.6mm

Voltage type

AC

Surge current capacity

-kA

Release characteristic

C

Rated insulation voltage Ui

500V

Leakage current type

A

Current limiting class

3

Rated fault current

0.03A

Rated voltage

240V

Over voltage category

3

Pollution degree

2

Power loss

1.56W

Number of poles (total)

2

Degree of protection (IP)

IP20

Number of protected poles

1

Width in number of modular spacings

1

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Ambient temperature during operating

-25 .. 55°C

Concurrently switching neutral conductor

Flush-mounted installation

Connectable conductor cross section solid-core

1.5 .. 16mm²

Anti-nuisance tripping version

Frequency

50/60 Hz

Connectable conductor cross section multi-wired

1.5 .. 16mm²

With interlocking device

Rated short-circuit breaking capacity according to EN 61009

6kA

Disconnection characteristic

Undelayed

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.