  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Release characteristicC
Rated insulation voltage Ui500V
Current limiting class3
Leakage current typeA
Frequency50/60 Hz
Rated voltage240V
Rated short-circuit breaking capacity according to IEC 60947-26kA
Rated current35A
Over voltage category3
Pollution degree2
With interlocking deviceNo
Degree of protection (IP)IP20
Width in number of modular spacings2
Power loss7.0W
Rated fault current0.03A
Surge current capacity-kA
Connectable conductor cross section multi-wired25 - 25mm²
Number of protected poles1
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core25 - 25mm²
Ambient temperature during operating- - -°C
Flush-mounted installationNo
Anti-nuisance tripping versionNo
Rated impulse withstand voltage Uimp4kV
Number of poles (total)2
Rated short-circuit breaking capacity according to EN 610096kA
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR255187R1354 | DS201 C35 A30 UL

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Release characteristic

C

Rated insulation voltage Ui

500V

Current limiting class

3

Leakage current type

A

Frequency

50/60 Hz

Rated voltage

240V

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Rated current

35A

Over voltage category

3

Pollution degree

2

With interlocking device

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Power loss

7.0W

Rated fault current

0.03A

Surge current capacity

-kA

Connectable conductor cross section multi-wired

25 .. 25mm²

Number of protected poles

1

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

25 .. 25mm²

Ambient temperature during operating

- .. -°C

Flush-mounted installation

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

2

Rated short-circuit breaking capacity according to EN 61009

6kA

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.