Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui500V
Built-in depth69mm
Rated fault current0.03A
Rated voltage240V
Rated current40A
Release characteristicC
Leakage current typeA
Power loss9.1W
Pollution degree2
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Frequency50/60 Hz
Number of protected poles1
Connectable conductor cross section solid-core25 - 25mm²
Over voltage category3
Surge current capacity-kA
Current limiting class3
Width in number of modular spacings2
Rated short-circuit breaking capacity according to IEC 60947-26kA
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicUndelayed
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section multi-wired25 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity according to EN 610096kA
Number of poles (total)2
Flush-mounted installationNo
With interlocking deviceNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR255187R1404 | DS201 C40 A30 UL

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

500V

Built-in depth

69mm

Rated fault current

0.03A

Rated voltage

240V

Rated current

40A

Release characteristic

C

Leakage current type

A

Power loss

9.1W

Pollution degree

2

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Frequency

50/60 Hz

Number of protected poles

1

Connectable conductor cross section solid-core

25 .. 25mm²

Over voltage category

3

Surge current capacity

-kA

Current limiting class

3

Width in number of modular spacings

2

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Undelayed

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

25 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Anti-nuisance tripping version

Rated short-circuit breaking capacity according to EN 61009

6kA

Number of poles (total)

2

Flush-mounted installation

With interlocking device

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.