Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC
Rated insulation voltage Ui440V
Leakage current typeA
Rated voltage230V
Release characteristicC
Power loss6.20W
Rated fault current0.03A
Pollution degree3
Width in number of modular spacings2
Over voltage category3
Frequency50 Hz
Surge current capacity0.25kA
Rated current25A
Current limiting class3
Built-in depth72mm
Rated short-circuit breaking capacity according to IEC 60947-210kA
Connectable conductor cross section solid-core- - -mm²
Number of protected poles2
Concurrently switching neutral conductorYes
Degree of protection (IP)IP20
Number of poles (total)2
Connectable conductor cross section multi-wired1 - 25mm²
Rated impulse withstand voltage Uimp4kV
Flush-mounted installationNo
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity according to EN 610096kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
With interlocking deviceNo
Ambient temperature during operating-25 - 55°C
Disconnection characteristicUndelayed
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR752140R1254 | DS202CR C25 A30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Rated insulation voltage Ui

440V

Leakage current type

A

Rated voltage

230V

Release characteristic

C

Power loss

6.20W

Rated fault current

0.03A

Pollution degree

3

Width in number of modular spacings

2

Over voltage category

3

Frequency

50 Hz

Surge current capacity

0.25kA

Rated current

25A

Current limiting class

3

Built-in depth

72mm

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Connectable conductor cross section solid-core

- .. -mm²

Number of protected poles

2

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Number of poles (total)

2

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated impulse withstand voltage Uimp

4kV

Flush-mounted installation

Anti-nuisance tripping version

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

With interlocking device

Ambient temperature during operating

-25 .. 55°C

Disconnection characteristic

Undelayed

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.