Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui440V
Release characteristicC
Rated fault current0.03A
Built-in depth72mm
Voltage typeAC
Rated voltage230V
Rated current32A
Surge current capacity0.25kA
Current limiting class3
Leakage current typeA
Width in number of modular spacings2
Pollution degree3
With interlocking deviceNo
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity according to IEC 60947-210kA
Power loss7.60W
Connectable conductor cross section solid-core- - -mm²
Over voltage category3
Rated impulse withstand voltage Uimp4kV
Ambient temperature during operating-25 - 55°C
Frequency50 Hz
Anti-nuisance tripping versionNo
Number of protected poles2
Number of poles (total)2
Disconnection characteristicUndelayed
Degree of protection (IP)IP20
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated short-circuit breaking capacity according to EN 610096kA
Concurrently switching neutral conductorYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR752140R1324 | DS202CR C32 A30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

440V

Release characteristic

C

Rated fault current

0.03A

Built-in depth

72mm

Voltage type

AC

Rated voltage

230V

Rated current

32A

Surge current capacity

0.25kA

Current limiting class

3

Leakage current type

A

Width in number of modular spacings

2

Pollution degree

3

With interlocking device

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Power loss

7.60W

Connectable conductor cross section solid-core

- .. -mm²

Over voltage category

3

Rated impulse withstand voltage Uimp

4kV

Ambient temperature during operating

-25 .. 55°C

Frequency

50 Hz

Anti-nuisance tripping version

Number of protected poles

2

Number of poles (total)

2

Disconnection characteristic

Undelayed

Degree of protection (IP)

IP20

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Concurrently switching neutral conductor

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.