Technical specifications

Rated fault current0.03A
Voltage typeAC
Leakage current typeA
Built-in depth72mm
Release characteristicC
Rated insulation voltage Ui440V
Rated voltage230V
Rated current40A
Surge current capacity0.25kA
Pollution degree3
Rated short-circuit breaking capacity according to IEC 60947-210kA
Width in number of modular spacings2
Current limiting class3
Degree of protection (IP)IP20
Concurrently switching neutral conductorYes
Frequency50 Hz
Connectable conductor cross section solid-core- - -mm²
Connectable conductor cross section multi-wired1 - 25mm²
Power loss8.92W
Number of protected poles2
Over voltage category3
Anti-nuisance tripping versionNo
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
With interlocking deviceNo
Ambient temperature during operating-25 - 55°C
Rated impulse withstand voltage Uimp4kV
Flush-mounted installationNo
Rated short-circuit breaking capacity according to EN 610096kA
Disconnection characteristicUndelayed
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR752140R1404 | DS202CR C40 A30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated fault current

0.03A

Voltage type

AC

Leakage current type

A

Built-in depth

72mm

Release characteristic

C

Rated insulation voltage Ui

440V

Rated voltage

230V

Rated current

40A

Surge current capacity

0.25kA

Pollution degree

3

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Width in number of modular spacings

2

Current limiting class

3

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Frequency

50 Hz

Connectable conductor cross section solid-core

- .. -mm²

Connectable conductor cross section multi-wired

1 .. 25mm²

Power loss

8.92W

Number of protected poles

2

Over voltage category

3

Anti-nuisance tripping version

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

With interlocking device

Ambient temperature during operating

-25 .. 55°C

Rated impulse withstand voltage Uimp

4kV

Flush-mounted installation

Rated short-circuit breaking capacity according to EN 61009

6kA

Disconnection characteristic

Undelayed